| Category | Description |
| Specifications |
| Optical Specifications | Attenuation | @1310nm | ≤0.35dB/km |
| @1383nm | ≤0.30dB/km |
| @1490nm | ≤0.24dB/km |
| @1550 | ≤0.20dB/km |
| @1625 | ≤0.23dB/km |
| Attenuation Non-uniformity | @1310nm, 1550nm | ≤0.05dB |
| Point Discontinuity | @1310nm, 1550nm | ≤0.05dB |
| Attenuation vs Wavelength | @1285nm - 1330nm | ≤0.03dB/km |
| @1525nm - 1575nm | ≤0.02dB/km |
| Zero Dispersion Wavelength |
| 1304nm-1324nm |
| Zero Dispersion Slope |
| ≤0.092ps/ (nm2·km) |
| Dispersion | @1550nm | ≤18ps/ (nm·km) |
| @1625nm | ≤ 23ps/ (nm·km) |
PMD Link Design Value (m=20 Q=0.01%) |
| ≤0.06ps√km |
| Maximum Individual Fiber |
| ≤0.2ps√km |
| Cable Cut-off wavelength(λ cc) |
| ≤1260nm |
| Macro Bending Loss (1turns; Φ10mm) | @1550nm | ≤0.30dB |
| @1625nm | ≤1.50dB |
| Mode Field Diameter | @1310nm | 8.6±0.4µm |
| @1550nm | 9.65±0.5µm |
| Dimensional Specifi-cations | Fiber Curl Radius |
| ≥4.0m |
| Cladding Diameter |
| 125±0.7µm |
| Core / Clad Concentricity |
| ≤0.5µm |
| Cladding Non-circularity |
| ≤0.7% |
| Coating Diameter |
| 242±5µm |
| Coating / Cladding Concentricity |
| ≤12µm |
| Mechanical Specifi-cations | Proof Test |
| ≥100kspi (0.7GPa) |
Environment Specification 1310 & 1550 & 1625nm
| Fiber Temperature Dependence | -60oC~ +85oC | ≤0.05dB/km |
| Temperature Humidity Cycling | -10oC~+85oC;up to 98%RH | ≤0.05dB/km |
| Heat Aging Induced Attenuation | 85±2oC | ≤0.05dB/km |
| Water Immersion Induced | 23±2oC | ≤0.05dB/km |
| Damp Heat | 85oC at 85% RH | ≤0.05dB/km |